Description:
• CAT6 (250MHz), 4-Pair, F/UTP-Foil Shielded, Plenum-CMP, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors, FEP Insulation, Polyester Separator, Overall Beldfoil Shield, Flamearrest® Jacket.
Insulation:
• Material: FEP - Fluorinated Ethylene Propylene
Outer Jacket Drain Wire AWG:
• AWG: 24
• Stranding: Solid
• Conductor Material: TC - Tinned Copper
Outer Jacket:
• Trade Name: Flamearrest
• Material: LS PVC - Low Smoke Polyvinyl Chloride
• Nom. Diameter (in.): 0.285
• Outer Jacket Ripcord: Yes
Usage (Overall):
Applications:
• Networking Horizontal Cable, 1000Base-T (Gigabit Ethernet), 100Base-T (Fast Ethernet), 10Base-T (Ethernet), 100BaseVG, ANYLAN, 155ATM, 622ATM, ANSI.X3.263 FDDI TP-PMD, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422, Noisy Environments, 250 MHz Category 6.
Mechanical Characteristics (Overall):
• Storage Temperature Range: -20°C To +75°C
• Installation Temperature Range: +5°C To +50°C
• Operating Temperature Range: -20°C To +75°C
• Bulk Cable Weight: 49 lbs/1000 ft.
• Max. Recommended Pulling Tension: 25 lbs.
• Min. Bend Radius/Minor Axis: 1 in.
• Min. Bend/Installation: 3 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 05/24/2007
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 6 - TIA 568.C.2
• Other Specification: UL Verified to Category 6
Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 14.000
• Maximum Capacitance Unbalance (pF/ft): 66.000
• Nominal Velocity of Propagation: VP (%): 72.000
• Maximum Delay (ns/100 m): 537.000
• Max. Delay Skew (ns/100 m): 30.000
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 8.200
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3.000
Flame Test:
• UL Flame Test: NFPA 262 Plenum Flame Test (UL910)(FT6)
• C(UL) Flame Test: FT6
• CSA Flame Test: FT6
Plenum/Non-Plenum:
• Plenum(Y/N): No
• Non-Plenum Number: 1351A
technical specification: | |
awg | 23 |
# pairs | 4 |
stranding | solid |
no. of conductors | 8 |
conductor material | bare copper |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable - nominal diameter (in.) | - |
belden cable part number | 1352A |