Description:
• 18 AWG stranded (41x34) High-conductivity TC conductors, EPDM rubber insulation, rayon braid, TC braid shield (85% coverage), cotton wrap, CPE jacket.
Insulation:
• Material: EPDM - Ethylene Propylene Diene Monomer Rubber
• Diameter (in.): 0.100
Outer Jacket:
• Material: CPE
Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -30°C To +60°C
• Non-UL Temperature Rating: 60°C
• Bulk Cable Weight: 54 lbs/1000 ft.
• Max. Recommended Pulling Tension: 138 lbs.
• Min. Bend Radius/Minor Axis: 3 in.
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 50
• Nom. Inductance (μH/ft): 0.19
• Nom. Capacitance Conductor to Conductor (pF/ft): 35
• Nom. Capacitance Cond. to Other Conductor and Shield (pF/ft): 60
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 6.8
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/1000 ft): 2.7
• Max. Operating Voltage - Non-UL: 600 V RMS
• Max. Recommended Current: 5.2 Amps/Conductor @ 25°C
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 18 |
# conductors | 2 |
stranding | 41x34 |
no. of conductors | 2 |
conductor material | tinned copper |
dia. (in.) | 0.047 |
outer shield - type | braid |
outer shield - material | tinned copper |
overall cable- nominal dia. (in.) | 0.290 |
belden cable part number | 8428 |