Description:
• 22 AWG stranded (7x30) tinned copper conductor, polypropylene insulation, twisted pairs individually shielded with Beldfoil® (100% coverage), overall PVC jacket and 22 AWG stranded tinned copper drain wire.
Pair Lay Length and Direction:
• Lay Length (mm): 44.450
• Twists (twist/m): 22.639 (Left Hand Direction)
Mechanical Charactertistics (Overall):
• Bulk Cable Weight: 104.174 Kg/Km
• Max. Recommended Pulling Tension: 698.367 N
• Min. Bend Radius/Minor Axis: 95.250 mm
Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.59058
• Nom. Capacitance Conductor to Conductor (pF/m): 98.43
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 180.455
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 49.215
• Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 34.779 Ohm/km
Plenum/Non-Plenum:
• Plenum (Y/N): No
• Plenum Number: 88778, 87778, 82778
technical specification: | |
awg | 22 |
# pairs | 6 |
stranding | 7x30 |
no. of conductors | 12 |
conductor material | tinned copper |
outer shield - material | unshielded |
overall cable- nominal dia. (mm) | 8.941 |
belden cable part number | 8778 |