Belden 9405 Cable 16 and 18 AWG Antenna Rotor Control UnShielded Stranded PVC Jacket Cable

Description:
• 6 - stranded (16x30) 18 AWG and 2 - 16 AWG stranded (19x28) tinned copper conductors, conductors cabled, PVC insulation, PVC jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride (16 and 18 AWG)
• Wall Thickness (mm): 0.483 (16 and 18 AWG )
• Insulation Resistance: 500 Megaohms/1000 ft. @ 500 V DC

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.8128

Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -20°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2464)
• Bulk Cable Weight: 129.473 Kg/Km
• Max. Recommended Pulling Tension: 805.124 N
• Min. Bend Radius/Minor Axis: 88.900 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CM
• AWM Specification: UL Style 2464 (300 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 13.124 (16 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 22.3108 (18 AWG)
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 4 Amps/Conductor @ 25°C (18 AWG)
• Max. Recommended Current: 4.9 Amps/Conductor @ 25°C (16 AWG)

Suitability:
• Sunlight Resistance: Yes

technical specification:
awg 16 and 18
# conductors 2 and 6
stranding 19x28 and 19x30
no. of conductors 8
conductor material tinned copper
outer shield - material unshielded
overall cable- nominal dia. (mm) 8.763
belden cable part number 9405