Description:
• 22 AWG stranded (7x30) tinned copper conductors, polypropylene insulation, twisted pair, overall Beldfoil shield (100% coverage), 22 AWG stranded TC drain wire, LSZH jacket.
Insulation:
• Material: PP - Polypropylene
• Wall Thickness (mm): 0.2032
Outer Shield Drain Wire AWG:
• AWG: 22
• Stranding: 7x30
• Material: TC - Tinned Copper
Outer Jacket:
• Material: LSZH - Low Smoke Zero Halogen
• Nom. Wall Thickness (mm): 0.8128
Usage (Overall):
Applications:
• Audio, Control, or Instrumentation for Marine Shipboard and Offshore use.
Mechanical Charactertistics (Overall):
• Operating Temperature Range: -30°C To +105°C
• UL Tempeature Rating: 105°C
• Bulk Cable Weight: 26.788 Kg/Km
• Max. Recommended Pulling Tension: 120.101 N
• Min. Bend Radius/Minor Axis: 44.450 mm
Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG-LS
• CEC/C(UL) Specification: CMG-LS
• EU Directive 2011/65/EU (ROHS II): Yes
• IEEE Specification: Std. 45 clause 23
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 08/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Other Specification: UL444, ABS Type Approval Certificate 05-HS500072B
Electrical Characteristics (Overall):
• Nom. Characteristic Impedance (Ohm): 45
• Nom. Inductance (μH/m): 0.55777
• Nom. Capacitance Conductor to Conductor (pF/m): 114.835
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 219.827
• Nominal Velocity of Propagation (VP %): 66
• Nominal Delay (ns/m): 4.9215
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 46.2621
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 46.9183
• Max. Operating Voltage - UL: 300 V RMS
• Max. Recommended Current: 2.9 Amps/Conductor @ 25°C
Flame Test:
• UL Flame Test: UL1685 FT4 Loading, Limited Smoke
• CSA Flame Test: FT4
• IEC Flame Test: 60332-1, 60332-3-22 (Category A)
• IEEE Flame Test: 1202
Suitability:
• Suitability - Indoor: Yes
• Suitability - Outdoor: Yes
• Sunlight Resistance: Yes
Plenum/Non-Plenum:
• Plenum (Y/N): No
technical specification: | |
awg | 22 |
# conductors | - |
stranding | 7x30 |
no. of conductors | 2 |
conductor material | tinned copper |
dia. (mm) | - |
outer shield - type | tape |
outer shield - material | aluminum foil-polyester tape |
overall cable- nominal dia, (mm.) | 4.064 |
belden cable part number | 9451SB |